Multidisciplinary Laboratory facilitates the clarification of the processes regarding biology and medical sciences provided in the Biophysics, Physiology and Pharmacology courses, and the monitoring of the mechanical, physical and biochemical functions and systems of the human body. In addition, laboratory supports such as method development, sample preparation, sample storage, etc. are provided for the researchers.
Multidisciplinary Laboratory consist of 6 different laboratories.
In Electrophysiology Laboratory 1 (EEG/EMG), the spontaneous electrical activities of neural system and muscles are recorded, and the recorded data are analyzed and their functions are evaluated.
In Electrophysiology Laboratory 2 de (EOG/Spirometer); the volume and capacity of lungs are measured by implementing passive and active respiratory function tests. Thus, functional status of lungs are estimated by utilizing these volume and capacity data.
In Electrophoresis Laboratory, molecules of biomolecules such as protein, DNA and RNA in the gel or paper medium which is electrocuted, are separated by their electrical loads and molecular weight.
In vitro and In vivo Organ Examination Laboratory, examine the functions of isolated heart, smooth and striated muscle preparates as well as their reactions to applied medication.
In Climatic Test Laboratory, the physiologic responses of biological systems in an artificially hot or cold environmental conditions.
In Viscosimeter Laboratory; viscosity measurement of body fluids are conducted for the diagnosis of various diseases.
General Information | Trainer is used for auscultating the normal and pathogen sounds of the heart/lungs. |
Brand & Model | NASCO |
Technical Details | Remote control |
General Information | It is used for testing respiratory functions |
Brand & Model | COSMED PONY FX |
Technical Details | Voltage (VAC): 100-240 |
General Information | It is used for electrophoretic separation of DNA and RNA molecules in agarose gel matrix. |
Brand & Model | VWR EC300XL2 |
Technical Details | Voltage (VAC): 0-150 |
General Information | It is used for electrophoretic separation of DNA and RNA molecules in agarose gel matrix. |
Brand & Model | VWR 700-0136 KROGEL MAXI 20, CVS10DSYS |
Technical Details | Voltage (VAC): 0-150 |
General Information | It is used for dissolving the gel by adjusting the required temperature and time for the electrophoresis procedure. |
Brand & Model | Arçelik MD574 |
Technical Details | Rotary table: Evet |
General Information | It is used for the elimination of chronic pain symptoms, relieving the muscle spasms, prevention or delaying of muscle atrophy due to immobility, increasing local blood circulation, training the muscles, maintaining and increasing the movement range. |
Brand & Model | WPI A320D |
Technical Details | Output current range (mA): 1-10 |
General Information | It is an equipment used for reproduction of bacteria samples and accurate usage of the device |
Brand & Model | Nukleon N1N12020 |
Technical Details | Voltage (VAC): 230, |
General Information | |
Brand & Model | |
Technical Details |
General Information | |
Brand & Model | |
Technical Details |
General Information | Electromagnetic flowmeter |
Brand & Model | TESLA Tes 1391 |
Technical Details | Frequency (Hz): 50/60 Resolution (Gauss/Tesla): 0.1/1 mil G, 0.01/0.1 micro T Range (Gauss/Tesla): 200/2000 mil G, 20/200 micro T |
General Information | It is used for diagnosing, identifying and understanding the cardiac dysrhythmia. |
Brand & Model | BIOPAC SYSTEMS INC MP36 |
Technical Details | 12VDC, 3AG, 250Volt, 1AMP Colored paper for visual warning |
General Information | It is used for precisely scaling the chemicals which will be used in research or application. Battery maximum capacity: 2000 g |
Brand & Model | Radwag WTB200 |
Technical Details | Accuracy [d]: 0.01 g IP: IP 43 RS 232×1 |
General Information | It is used for homogenously mixing and heating the samples which are used during the research and application. |
Brand & Model | MISUNG SCIENTIFIC MS-300HS |
Technical Details | Mixing speed range (RPM): 100-1500 Max temperature (° C): 380 |
General Information | It is used for measuring the alkalinity, acidity and activity of hydrogen ion in water based solutions, and electrical potential difference of a pH electrode and a reference electrode. |
Brand & Model | ADWA AD1030 |
Technical Details | 3 digit reading |
General Information | It is used for creating a pure supernatant and separating the liquids of emulsion or suspension which contains small particles. |
Brand & Model | Nüve NF400 |
Technical Details | Speed range (RPM): 1000-4100 Voltage (VAC): 200-230 Frequency (Hz): 50/60 Power (W): 450 Maximum RCF: 2.142 xg 2.819 xg 2.011 xg Weight (Kg): 26 Maximum capacity: 4 x 100 ml Motor: Maintenance-free induction motor |
General Information | It is used for measuring the quantity of the substance which is looked for in the dispersion by identifying the intensity of light penetrated through the dispersion. |
Brand & Model | VWR UV-1600 PC |
Technical Details | Range 190-1100 nm, Graphic LCD: 128*64 pixel |
General Information | The equipment measures the cycle, speed and frequency of rotary or mobile particles. |
Brand & Model | Lutron DT-2249A |
Technical Details | Voltage (VAC): 220 |
General Information | It is used for slowly heating the samples in a fixed temperature, incubation or preserving its temperature without directly subjecting the sample to the fire during research and practices. |
Brand & Model | Nükleon NCS-30 |
Technical Details | Capacity (L): 30 |
General Information | Vortex aims to evenly mixing the specimen that is to be used during research or application. |
Brand & Model | SCILOGEX MX-S |
Technical Details | Voltage (VAC): 220-230/110-120 |
General Information | Viscosity is the resistance the liquid and semiliquid materials show against the flow and changes in shape. Viscosimeter is used for measuring the viscosity of biological liquids. |
Brand & Model | Harkness |
Technical Details | - |
Öneri ve şikayetlerimi kime/nereye bildirmeliyim?
İstanbul Aydın Üniversitesi Sağlık Bilimleri Eğitim ve Araştırma Laboratuvarlarından hizmet almak istiyorum. Nasıl bir yol izlemem gerekiyor?
İAÜ Sağlık Bilimleri Laboratuvarları kurulduğu günden beri ülkemizin bütün akademik birimlere, kamuya ait ve özel kurumlara hizmet vermektedir. Hizmet kural ve şartlarımız internet sitemizde Hizmetler bölümünün altında açıklanmaktadır.
İstanbul Aydın Üniversitesi’ne ulaşım nasıl sağlanır?
Toplu Taşıma ile “BEŞYOL” metrobüs durağından inerek 5 dakika yürüme mesafesi ile ulaşım sağlanabilir.
Şahsi araç ile Beşyol, İnönü Cd. No:38 adresi ile ulaşım sağlanabilir.
Tübitak, BAP, AB projesi yazıyorum hizmet alımı için sizden proforma alabilir miyim?
Laboratuvar | Cihaz Adı | Test Adı/Tedavi Parametreleri/Yapılan Uygulamalar |
---|---|---|
Multidisciplinary Laboratory | Spectrophotometer | Bodily fluid quantitation |
Viscosimeter Laboratory | Viscosimeter | Bodily fluid viscosity |
Electrophysiology (EOG/Spirometer) Laboratory | Spirometer | Forced Vital Capacity (FVC) |
Electrophysiology (EOG/Spirometer) Laboratory | Spirometre | Bronchial Provocation Test (FVC Pre) |
Electrophysiology (EOG/Spirometer) Laboratory | Spirometre | Maximum Voluntary Ventilation (MVV) |
Electrophysiology (EOG/Spirometer) Laboratory | Spirometre | VC |
Electrophysiology (EOG/Spirometer) Laboratory | Spirometre | MIP/MEP |
Electrophysiology (EOG/Spirometer) Laboratory | Spirometre | Air way resistance |
Electrophysiology (EOG/Spirometer) Laboratory | Spirometre | Slow Vital Capacity (SVC) |