Medical Skill Laboratory carries out training for application processes on models and trainrs for the acquisition of medical interventional skills and medical hand skills with simulations of real environments, and the use of devices in applications with device requirements.
IAU Medicine Faculty Medical Skill Laboratory consist of six separate laboratories in which 3 Patient Simulation Unit, 2 Polyclinic Simulation Unit and 1 Medical Skill Laboratory.
In Patient Simulation Unit, procedures concerning the simulations conducted on training dummies and models through bedside monitors are taught.
In Polyclinic Simulation Unit, procedures concerning the training about measuring the blood pressure and temperature, respiratory rate and pulse rate.
In Medical Skill Laboratory, procedures concerning the training and simulations of resuscitation, suture, vascular access, injection, gastric tube, and bladder tube are conducted on training dummies and models by reach student.
General Information | Trainer is used for practicing the CPR (cardiopulmonary resuscitation), a first aid technique implemented for resuscitating the patients, in case of a sudden heart arrest or respiratory arrest. |
Brand & Model | Simulaids |
Technical Details | Compatible with real-life size infant anatomy. Developed for implementing CPR. Rib cage and expansion are observable. Mobile head and jaw for opening airway. Full body. Weight: 1.58 kg, Size: 66 x 20.3 x 20.3 cm |
General Information | Trainer is used for practicing the CPR (cardiopulmonary resuscitation), a first aid technique implemented for resuscitating the patients, in case of a sudden heart arrest or respiratory arrest. |
Brand & Model | - |
Technical Details | Compatible with real-life size child anatomy. Half body. Developed for implementing CPR. Rib cage and expansion are observable. Mobile head and jaw for opening airway. Weight: 22.25 kg, Size: 44 x 28 x 21 cm |
General Information | Defibrillator is used for turning back the abnormal rhythm of the heart to a normal rhythm. Electric energy applied to fibrillated and stopped heart in the form of shock causes a stimuli and contraction. In order to apply shock to the heart with the defibrillator, the heart must have ventricular fibrillation (fatal arrhythmia). Defibrillator is used for the treatment of rhythm disorders in the heart. |
Brand & Model | Nıhon Kohden / TEC-5521K |
Technical Details | Optional Sp02 and CO2, Biphasic waveform. Single-use pad adaptor cable and single-use pad AED. Hands-free defibrillation, CPR timer sound and optional automatic charge for voice command, Clear, Clear TFT colored LCD screen, 2 waveform images. Fast ECG saving for monitoring after defibrillation Highly reliable high voltage capacitor prevents defibrillator errors. Voice and ECG recording in SD. |
General Information | It is used for measuring the body temperature. |
Brand & Model | PLUSMED |
Technical Details | Measurement range: 32.0°C – 42.9°C (90.0°F-109.9°F) (°C/°F unit is selected by the manufacturer.) Battery: One 1,5V DC (LR41 or SR41 type, UC 392) |
General Information | It is used for practicing the catheterization and removal of the urine through catheter. |
Brand & Model | GAUMARD SCİENTİFİC |
Technical Details | Weight: 7.576 kg |
General Information | Realistic trainer is used for nursing care and improve its practices. |
Brand & Model | Gaumard Scientific |
Technical Details | Realistic soft skin for the face. Mobile airway compatible with anatomy. Tongue, epiglottis, vocal cords and larynx. Mobile jaw. Ear canal is compatible with eardrops and ear washes. Compatible with NT, NP and OP practices. Compatible with intubation and aspiration. Waist and abdomen motions are same as human motions. Realistic heart, liver, lungs, stomach and ribs for implementing various CPR techniques. Advanced hand and arm for IV-IM and sub-Q techniques. Changeable male and female breasts, left breast includes carcinoma. Changeable male and female genitalia. Compatible with male and female catheterization. Colostomy, ileostomy and enema can be conducted for holes in the lower abdomen. Vagina and cervix compatible with smear tests. Two separate bladder. |
General Information | ECG’s for adults and children can be conducted on the multifunctional trainer. It is used for defibrillation procedure. Blood pressure’s rhythms can be monitored, and the rhythm levels can be adjusted via blood pressure simulator. Trainer has changeable skin and vascular structure which is compatible with creating vascular access |
Brand & Model | NASCO |
Technical Details | Appropriate body structure which is flexible and coherent for CPR. Appropriate oral structure for oral and nasal intubation. CPR feature. Cricoid cartilage for Sellick maneuver. Suction. Oral, nasal and digital intubation. Defibrillation specifications: Maximum 360 joule mechanism energy consumption. Manual, semi-automatic and automatic defibrillation, 4 ECG and 2 defibrillation. Blood pressure: Systolic diastolic levels, heart rate and voice setting, adjustable korotkoff phase and auscultatory space. IV specifications: Jointed biceps for antecubital and dorsal entrance, bony landmark for intramuscular injection in the shoulder, and changeable skin and veins. ECG simulator: ECG simulator includes 17 adult and children heart rhythm. |
General Information | It is used for conducting training on dummies for intradermal injection. |
Brand & Model | - |
Technical Details | Removable skin form. |
General Information | It is used for visual and tactile learning in intramuscular injections. Trainer simulates the half hip and it is wearable, and compatible with water infusion. Digital compartment located in the trainer provides visual and auditory warnings, which are green for correct and red for incorrect injection. |
Brand & Model | M153 |
Technical Details | Realistic model, compatible with human anatomy. Half-hip simulator. Compatible with intramuscular injection. Digital compartment located in the trainer provides visual and auditory warnings, which are green for correct and red for incorrect injection. Hip simulator can be wore. Intramuscular injection practice with compatibility with water infusion. Durable, soft and realistic skin does not show any marks of the prior injection. Carrier bag and user manual. |
General Information | It is used for practicing the correct vein entrance. |
Brand & Model | NASCO LİFE FORM |
Technical Details | Trainer is durable and does not deform. Changeable veins and skin. |
General Information | It is used for practicing the intravenous injection practices. |
Brand & Model | 3B Scientific |
Technical Details | Easy to clean silicone skin surface. Changeable veins and skin
|
General Information | It is used for practicing the catheterization and removal of the urine through catheter. |
Brand & Model | GAUMARD SCİENTİFİC |
Technical Details | Weight: 7.576 kg |
General Information | It is used for normal and pathogen voices of heart and lungs. |
Brand & Model | NASCO |
Technical Details | Remote control |
General Information | It is used for taking the temperature more quickly and accurately than other measuring methods by takin the temperature from the ear. |
Brand & Model | TRULY / TET 350 |
Technical Details | Reliable measurement in 1 second LCD screen 3 colored screen for the temperatures Ultra comfortable soft tip Lens tip eliminating the possibility of error when measured consecutively Memory of last 8 measurement Durable storage box Infrared technology NIR (Near Infrared) method Measurement range: 24°C ~ 42°C (93.2°F ~ 107.6°F) Contingency percentage: ±0.2°C (±0.4°F) Dimensions: 33(W) x 42(D) x 143(H) mm Battery: 2 x AAA 3V (approximately 5000 measurement)
|
General Information | Laryngoscope is used as a medical aid for imaging the trachea during the intubation. |
Brand & Model | MediLine |
Technical Details | Blades are compatible with intubation, stainless steel blade and handle, 3 blades in a box (No. 1,2,3), and battery. |
General Information | Trainer is used for practicing gastrointestinal procedures and NG tube placements through nose and mouth. |
Brand & Model | Tellyes Scientific |
Technical Details | Shape compatibility with nasogastric catheter entrance. Nasogastric catheter is sensed, given liquid can be heard in the stomach with stethoscope, the liquid can be discharged. |
General Information | It is used for practicing and monitoring the retina, macula and optical disc structures. |
Brand & Model | - |
Technical Details | Set in a box Manually adjustable light Handle screw lock system Ophthalmoscope headpiece is included Ophthalmoscope vacuum lenses can be adjusted -25 to +40 with 24 diopter settings |
General Information | Defibrillator is used for turning back the abnormal rhythm of the heart to a normal rhythm. Electric energy applied to fibrillated and stopped heart in the form of shock causes a stimuli and contraction. In order to apply shock to the heart with the defibrillator, the heart must have ventricular fibrillation (fatal arrhythmia). Defibrillator is used for the treatment of rhythm disorders in the heart. |
Brand & Model | Nıhon Kohden/ 2100K |
Technical Details | Auditory instructions, Biphasic, ECG data registry of the last 90 minutes, connection and transfer to the computer with wireless Bluetooth feature, AED Report Viewer, appropriate for using on all ages
|
General Information | It is used for conducting training on dummies for intradermal injection. |
Brand & Model | - |
Technical Details | Removable skin form. |
General Information | It is used for practicing on the simulator in which the person’s floating or drowning in water. |
Brand & Model | Simulaids |
Technical Details | Mobile joints. Manufactured from durable plastic and stainless steel.
|
General Information | It is used for practicing on the hard cut and suture practices in the open surgery operations with suture pad. |
Brand & Model | 3B Scientific |
Technical Details | 3 layered skin, compatible with intradermal injection, can be carried. |
General Information | It is used for measuring the pulse and blood pressure from forearm or wrists. |
Brand & Model | ERKA |
Technical Details | Manual Blood Pressure Device Profi Model: 48 mm diameter scale, double hose, hook, adhesive black cuff Switch Model: 56 mm scale, single hose, right/left hand use, adhesive yellow cuff Sensivite Model: 47 mm diameter double membrane single drum, for cardiology or professional use. |
General Information | Defibrillator is used for turning back the abnormal rhythm of the heart to a normal rhythm. Electric energy applied to fibrillated and stopped heart in the form of shock causes a stimuli and contraction. In order to apply shock to the heart with the defibrillator, the heart must have ventricular fibrillation (fatal arrhythmia). Defibrillator is used for the treatment of rhythm disorders in the heart. |
Brand & Model | Zoll / Aed Plus |
Technical Details | CPR voice assistant CPR voice command |
General Information | Intubation trainer is used for the implementation of intubation and suction techniques without anesthesia. Trainer is in the size of a normal baby’s head and should be positioned as slightly anterior. It should come with the jaw, tongue, teeth, mouth and oral-nasal pharynx, epiglottis, arytenoid, false cords, trachea, lungs, esophagus and stomach organs with anatomically correct features. Oral, digital and nasal intubation practices as well as E.T., O.A., P.T.L and Combitube can be performer. Arterial press |
Brand & Model | AMBU |
Technical Details | Left side of the head is open. Pharynx and trachea walls are transparent which helps with monitoring the intubation tube while it is going down. Electronic teeth sensor. Intubation hardness settings can be adjusted. Ambu Airway Trainer is designed for the training purposes of all modern airway management techniques. Trainings concerning the orotracheal tubes, laryngeal masks, Combitube, nasotracheal tubes, endotracheal tubes and guedel airway locations. |
General Information | |
Brand & Model | NASCO LİFE FORM |
Technical Details | Model is normal human sized and slightly anterior positioned. Simulator is for implementing the intubation, ventilation and suction procedures for non-anesthetic patients. ET, EOA, PTL procedures as well as oral, nasal and digital intubation can be conducted. Anatomically correct jaw, tongue, mouth, oral and nasal pharynx, epiglottis, false cords, and trachea, arytenoid, lungs, and esophagus and stomach organs. Comes with lubricant and hard cover carrier bag. |
General Information | - |
Brand & Model | - |
Technical Details | -
|
General Information | |
Brand & Model | 3B Scientific |
Technical Details | Spring-loaded form with 5-6 cm depth. Developed for implementing CPR technology. Observable ribcage and motion. Mobile head and jaw for opening airways. Full body form. |
*
Laboratuvar | Cihaz Adı | Test Adı/Tedavi Parametreleri/Yapılan Uygulamalar |
---|---|---|