Radiotherapy Laboratory

Radiotherapy laboratory aims to offer the equipment used for oncological care, support, preparation or treatment to the students for educational purposes.

Immobilization, CT scanning, preparation before the treatment, head-neck mask, fixing the position of the patient on vacuum bed to the patients who will be provided with radiotherapy, and providing personal equipment is among the applied information provided in the course of training and education processes.

The equipment in the laboratories are for demonstration purposes and they do not have radiation field.

Students can further into their career upon their graduation with the applied and practical education they have received in addition to their theoretical education and having the experience of practicing in the laboratories.

Administrative Staff

Vice Rector

Prof. Dr. Ahmet İLVAN

[email protected]

444 1 428 - 56102

Laboratories Coordinator

Öğr. Gör. Veli Bülent UÇAR

[email protected]

444 1 428 - 14628

Academic Staff

Radiotherapy Department Head

Öğr. Gör. Zeynep Duygu TİRYAKİOĞLU

[email protected]

444 1 428 - 57006

Dr.

Füsun ÇETİN

[email protected]

444 1 428 - 57003

Qualified Instructor

Burhan ÇABUK

[email protected]

444 1 428 - -

Radiotherapy Laboratory

Compound Melting Pot

General Information The equipment is used for liquidizing process of the materials by heating.
Brand & Model Mt-801.5 DEX
Technical Details

0-100 C

Thermostat

Steel vault reservoir

Feature of liquidizing the solid materials by heating

Electron Foam Cutter

General Information It is used for shaping the materials such as foam and polystyrene in the desired forms.
Brand & Model MT 900 EX
Technical Details

200 V

Foam cutting by heating string

Heater Tank

General Information It is mandatory to create a mask to fixate the head in cases such as neck and head tumors. The device is used for gaining flexibility to the mask by the interaction between the mask and hot water.
Brand & Model Radon/ R3 Su Isıtma
Technical Details

Nominal heating power 70 kW
The mold is produced by the solid mold’s interaction with hot water.

Shoulder Board

General Information It provides the immobilization of the patient’s body at the desired angle for MRI.
Brand & Model Radon / PVC
Technical Details

Adjustable according to patient’s position, height and weight.

Patient’s head is rested on the silicone pillow which is in the middle of two elbow fixing apparatus.

Vacuum Pump

General Information It is used for vacuum operations in the cooling systems. The maximum capacity should be at least 2.10-5 bar, and the flow rate should be at least 150 liters/minute.
Brand & Model Schmalz Vacuum Value
Technical Details

Oil capacity 220-380 ml

Power 250 W

220 V 50 Hz

Safety valve max. 10-7 bar liter/second

Tomography

General Information It is used in diagnosing emergency diseases and internal organ diseases, differential diagnosis, treatment planning, control, monitoring and screening purposes.
Brand & Model Ax 180 G
Technical Details

1 screening unit and detector system

X-ray generator and tube

Automatic injection pump

CD-DVD robot unit

Generator output should at least be 42 kW.

Heating rate of tube anode should at least be 745/kHU/second

Vacuum Bed

General Information It is used for fixing the patient on a levelled surface and preserving the position during the radiation therapy.
Brand & Model Radon / PVC
Technical Details

Fundamentally, they are thick and durable bags made out of plastic.

The interior of these bag are filled with small polystyrene bubbles.

Valve on the edge of vacuum bed is used for the deaeration.

Long straps are on the each side of the bed.