Radiotherapy laboratory aims to offer the equipment used for oncological care, support, preparation or treatment to the students for educational purposes.
Immobilization, CT scanning, preparation before the treatment, head-neck mask, fixing the position of the patient on vacuum bed to the patients who will be provided with radiotherapy, and providing personal equipment is among the applied information provided in the course of training and education processes.
The equipment in the laboratories are for demonstration purposes and they do not have radiation field.
Students can further into their career upon their graduation with the applied and practical education they have received in addition to their theoretical education and having the experience of practicing in the laboratories.
General Information | The equipment is used for liquidizing process of the materials by heating. |
Brand & Model | Mt-801.5 DEX |
Technical Details | 0-100 C Thermostat Steel vault reservoir Feature of liquidizing the solid materials by heating |
General Information | It is used for shaping the materials such as foam and polystyrene in the desired forms. |
Brand & Model | MT 900 EX |
Technical Details | 200 V Foam cutting by heating string |
General Information | It is mandatory to create a mask to fixate the head in cases such as neck and head tumors. The device is used for gaining flexibility to the mask by the interaction between the mask and hot water. |
Brand & Model | Radon/ R3 Su Isıtma |
Technical Details | Nominal heating power 70 kW |
General Information | It provides the immobilization of the patient’s body at the desired angle for MRI. |
Brand & Model | Radon / PVC |
Technical Details | Adjustable according to patient’s position, height and weight. Patient’s head is rested on the silicone pillow which is in the middle of two elbow fixing apparatus. |
General Information | It is used for vacuum operations in the cooling systems. The maximum capacity should be at least 2.10-5 bar, and the flow rate should be at least 150 liters/minute. |
Brand & Model | Schmalz Vacuum Value |
Technical Details | Oil capacity 220-380 ml Power 250 W 220 V 50 Hz Safety valve max. 10-7 bar liter/second |
General Information | It is used in diagnosing emergency diseases and internal organ diseases, differential diagnosis, treatment planning, control, monitoring and screening purposes. |
Brand & Model | Ax 180 G |
Technical Details | 1 screening unit and detector system X-ray generator and tube Automatic injection pump CD-DVD robot unit Generator output should at least be 42 kW. Heating rate of tube anode should at least be 745/kHU/second |
General Information | It is used for fixing the patient on a levelled surface and preserving the position during the radiation therapy. |
Brand & Model | Radon / PVC |
Technical Details | Fundamentally, they are thick and durable bags made out of plastic. The interior of these bag are filled with small polystyrene bubbles. Valve on the edge of vacuum bed is used for the deaeration. Long straps are on the each side of the bed. |
*
Laboratuvar | Cihaz Adı | Test Adı/Tedavi Parametreleri/Yapılan Uygulamalar |
---|---|---|